Title: REQUEST FOR RECOMMENDATION TO THE TOWN COUNCIL ON PROPOSED SITE PLAN FOR 1007 ELECTRIC AVE SE, NAVY FEDERAL CREDIT UNION, FOR THE INSTALLATION OF TWO-WAY DRIVE-THROUGH ATM FACILITY.
Attachments: 1. 01 - PC Staff Report -1007 Electric Ave SE - NFCU - ATM Site Plan, 2. 02 - NFCU - ATMs - Application & Authorization Form, 3. 03 - NFCU - ATMs - Relocation_Site Plan, 4. 04 - NFCU - BZA Approved Variance Order - 1007 Electric Ave SE, 5. 05 - NFCU - ATMs - BAR Approved Renderings & Site Photos, 6. 06 - Relevant Code Sections, 7. PC Staff Presentation - NFCU ATMs

Subject:

Title

Request for recommendation to the Town Council on proposed site plan for 1007 Electric Ave SE, Navy Federal Credit Union, for the installation of two-way drive-through ATM facility.

Body

Navy Federal Credit Union (NFCU) proposes relocating the existing drive-through automated teller machine (ATM) facility from the 820 Follin Lane SE (HQ1) property to the 1007 Electric Avenue SE property (HQ2). The ATM provides banking services for Navy Federal Credit Union members. The proposed drive-through is two lanes, one ATM serving a lane in each direction.

 

Two components of the proposal are not in conformance with zoning in the CP Corporate Park zoning district but are allowable with approvals of variances from the Board of Zoning Appeals (BZA). On April 16, 2025, the BZA granted the following two variances: 1) allowing the new drive-through ATM facility to within the front yard setback; and 2) allowing the new facility to have two lanes.

 

More detail on the overall proposal, including the variances, are provided in Attachment 1, the Staff Report, which also describes the additional attachments.

 

Per Section 18-836.2E of the Town Code, the site plan requires review and recommendation by the Planning Commission before final approval by the Town Council.

 

Attachments:

01 - Staff Report

02 - Application & Authorization

03 - Site Plan                     

04 - BZA Approved Variance Order

05 - BAR Approved Renderings & Site Photos

06 - Relevant Code Sections

 

PROPOSED/SUGGESTED MOTION

Recommended Action

"I move to recommend approval to the Town Council of the proposed site plan for a drive-through ATM facility for the Navy Federal Credit Union property located at 1007 Electric Ave SE."

OR

"I move to recommend approval to the Town Council of the proposed site plan for a drive-through ATM facility for the Navy Federal Credit Union property located at 1007 Electric Ave SE, with the following conditions:

(Planning Commissioners state conditions of approval individually)

1.

2.

3."

OR

“I move to recommend denial to the Town Council of the proposed site plan for a drive-through ATM facility for the Navy Federal Credit Union property located at 1007 Electric Avenue SE.”

OR

Other action deemed necessary by the Planning Commission.